Analytical Testing

Composition Qualitative and Quantitative Analysis

time2018-06-01

1

Inorganic anions

Measurement

F、Cl、NO2、Br、NO3、PO43−、SO32−、SO42−

Sample

Water and wastewater

Instrument

Ion Chromatograph (Thermofisher)

Typical Project

Determination of inorganic anions (Fluoride ion, Chloride ion, Nitrite ion, Bromide ion, Nitrate ion, Phosphate ion, Sulfite ion, Sulfate ion) in water

Standard

HJ 84-2016 Water quality — Determination of inorganic anions (F-, Cl-, NO2-, Br-, NO3-, PO43-, SO32-, SO42-) — Ion chromatography


2

Powder X-Ray Diffraction

Measurement

Qualitative and quantitative analysis of metal and non-metal polycrystalline samples; 

Phase analysis of thin-film materials and texture and stress analysis of materials; 

Crystallinity and crystalline grain size calculation; 

Crystalline deformation determination; 

Small Angle scattering and particle size distribution of nanometer materials

Sample

Powder

Instrument

Powder X-Ray Diffractometer (Rigaku)

>> Specifications: 1) Wide angle goniometer (θ-θ), 2θ range from −10° to 168°

>> Accessories: 1) SAXS unit (small angle measurement); 2) High temperature attachment

Typical Project

Phase analysis

Standard

JY/T 009-1996 General rules for X-ray polycrystalline diffractometry


3

Ultraviolet & Visible Spectrophotometry Test

Measurement

Total nitrogen; Ammonia nitrogen; Total phosphorus

Sample

Water and wastewater

Instrument

Ultraviolet & Visible Spectrophotometer (PerkinElmer)

>> Specifications: 1) Light sources: deuterium lamp, iodine-tungsten lamp; 2) Double light path system;3) Wave range from 190 nm to 1100 nm

Typical Project

Determination of total nitrogen in water;

Determination of ammonia nitrogen in water;

Determination of total phosphorus in water

Standards

HJ 636-2012 Water quality — Determination of total nitrogen — Ultraviolet spectrophotometric method for alkaline potassium persulfate digestion

HJ 535-2009 Water quality — Determination of ammonia nitrogen — Nessler's reagent spectrophotometry

GB/T 11893-1989 Water quality — Determination of total phosphorus — Ammonium molybdate spectrophotometric method


4

Gas Chromatographic Measurement

Measurement

Separation of low boiling point and multi-component mixture; Separation of isomers;

Detection of trace components

Sample

Water and wastewater

Instrument

Gas Chromatograph (Agilent)

>> Specifications: 1) Automatic liquid sampler (ALS), headspace sampler; 2) Detectors: Electron capture detector (ECD), Flame ionization detector (FID)

Typical Project

Determination of methanol and acetone in water

Standard

HJ 895-2017 Water quality — Determination of methanol and acetone — Headspace gas chromatography



5

Gas Chromatography - Mass Spectrometry Measurement

Measurement

Separation and identification of complex organic compounds;

Qualitative and quantitative analysis of complex organic compounds.

Sample

Water and wastewater

Instrument

Gas Chromatograph – Mass Spectrometry (GC-MS) (Agilent)

>> Specifications: 1) Automatic liquid sampler (ALS), headspace sampler; 2) Detectors: Electron capture detector (ECD), Flame ionization detector (FID)

Typical Project

Determination of nitroaromatics in water

Standard

HJ 716-2014 Water quality — Determination of nitroaromatics — Gas chromatography-mass spectrometry


6

High Performance Liquid Chromatographic Measurement

Measurement

Separation of high boiling point and thermally unstable organic mixtures;

Efficient separation and analysis of biochemical samples;

Organic matter identification; Purity/content determination; Content of proteins

Sample

Drug

Instrument

High Performance Liquid Chromatograph (HPLC) (Agilent)

>> Specifications: 1) Autosampler/Vialsampler; 2) Detector: VWD/FLD Spectra

Typical Project

Organic matter identification; Purity/content determination; Content of proteins

Standards

Chinese Pharmacopoeia 2015 Vol Ⅳ general rule 0512 (High performance liquid chromatography);

Chinese Pharmacopoeia 2015 Vol Ⅳ general rule 0713


7

Near Infrared Spectra (NIR)

Measurement

Quantitative testing of solid and liquid samples

Sample

Solid, liquid

Instrument

Near Infrared Spectrum Analyzer (ThermoFisher)